AMD software and drivers are designed to work best for up-to-date operating systems. Windows 10 - 64-Bit Edition. Radeon Software.By clicking the 'Download. NVIDIA has been working closely with Microsoft on the development of Windows 10 and DirectX 12. Coinciding with the arrival of Windows 10, this Game Ready driver includes the latest tweaks, bug fixes, and optimizations to ensure you have the best possible gaming experience.
Windows 10 Compatibility If you upgrade from Windows 7 or Windows 8.1 to Windows 10, some features of the installed drivers and software may not work correctly.
Scanning Methods
electronic linear
electronic convex
electronic microconvex
electronic phased array
scanning depth: 2 – 30 cm
Imaging Modes
B, B+B,4B, B+M, M
In B mode:
Spatial Compound
Wide View Imaging (Linear probes)
B-steer Imaging
Tissue Harmonic Imaging with Pulse Inversion (iTHI)
CFM – Color Flow Mapping
PDI – Power Doppler
DPDI – Directional Power Doppler
PWD – Pulsed Wave Doppler
CWD – Continuous Wave Doppler
B+PWD/CWD (Duplex)
B+CFM/PDI/DPDI+PWD/CWD(Triplex)
High Pulse Repetition Frequency (HPRF)
PanoView – Panoramic Imaging (option)
3DView – Rendering 3D (option)
Transducers
Frequency range: 1,5 – 18,0 MHz
multifrequency
automatic transducer recognition
number of ports:
SmartUs EXT-1M 1 port
SmartUs EXT-3M 3 ports
Image Processing
High Line Density scan mode for better resolution
TGC Control, 5-10 sliders (customizable) 40 dB
dynamic range: 120 dB, 8 values
overall gain control
M – mode sweep speed control
acoustic power control
variable frame averaging
brightness, contrast controls
advanced gamma control: 8 fixed curves, 8 user defined (custom)
scan direction, rotation, up-down controls
negative / positive control
bi-linear interpolation
echo enhancement control
noise rejection function
Advanced Speckle Reduction Imaging and structure improvement
PureView: 8 algorithms
NeatView: 8 algorithms
QuickView: 8 algorithms
Focusing
digital transmit focusing: variable, 8 zones
digital receive focusing: point to point, dynamic
Color Doppler
Abit siluro gf3 ti200v driver download for windows 10. PRF variable: 0.5-10 kHz
wall filter settings: 3 steps (5%, 10%, 15% PRF)
gain control: 50 dB
acustic power control
steering angle for linear transducers: up to ±25°
CFM palette: 10 color maps
PDI/DPDI palette: 14 color maps
B/Color priority control
color threshold control
CFM baseline control
Doppler frequency selection: 2 frequencies / each transducer
color frame averaging (persistance): 8 values
Transparent Color Mapping (TCM): 10 values
Menu-Options Color Doppler settings controls:
Real-time spatial filter: 4 values
Line Density: 7 values
Pulse length: 7 values
CFM Packet size: 4 values
PDI/DPDI Packet size: 4 values
PDI/DPDI Dynamic Range: 40 dB
PDI/DPDI Digital Gain scale
Pulsed Wave Doppler / Continuous Wave Doppler
PRF variable: 1-15 kHz
wall filter settings: 16 steps (2.5-20% PRF)
gain control: 50 dB
acustic power control
steering angle for linear transducers: ± 25°
stereo sound: volume control
correction angle ±85°
baseline control
sweep speed control
PWD/CWD palette: 12 color maps
Doppler frequency selection: 2 frequencies / each transducer
PWD/CWD Digital gain control: 5 values
real-time trace line with automatic calculation of spectrum parameters
Menu–Options PWD/CWD settings controls:
PWD/CWD Dynamic Range: 80 dB
PWD/CWD Smoothing
Spectral Averaging
Automatic Image Optimization
single click auto adjustment:
B-image: gain, dynamic range, TGC sliders
Color Doppler: CFM/PDI/DPDI gain
PWD/CWD: baseline, invert, PRF
Ultrasound Imaging
ultrasound image size: automatically adjustable to screen resolution
gray scale: 256
color scale: 256
full motion and full size real-time ultrasound imaging, in Parallel Beamforming mode up to 400 fps (depending on selected scan depth, scan angle, focus mode, High Line Density setting, computer speed)
cineloop recording/play: several thousands frames (depends on computer memory size and
scan mode)
zoom mode: from 60% to 600% in all modes (Scan, Freeze, B, B+B, 4B, Doppler modes, Mzoom,
cineloop and etc)
viewing area variable for frame rate maximizing: 6 steps
thumbnail mode: up to 32 images
'Freeze' mode
'Auto Freeze' mode
Functions
mouse / trackball / keyboard /touch screen operation
unlimited programmable presets for clinically specific imaging
body marks, anatomical icons with transducer position indicator
annotations and drawings
echo-guided biopsy trace and target settings, calibration
patient reporting and archiving:
Creation of patient folder for archiving patient data, reports, images/video
Customization of report: templates, report layout (patient data, diagnostic images,
measurements and calculations, curves and diagrams, comments, etc.)
direct e-mail sending with image / video / report attachment via Internet
DICOM file push to server
printing to PC printer or thermal printer
multi-monitor support
full screen and window mode
ultrasound scanner monitor and system information
Telemedicine functions with remote control of the system, for diagnostic consultation,
application training and technical support
Freeware software upgrades
User Interface Customization
set of predefined skins for software interface
set of predefined buttons images
classic ultrasound interface
full screen and window mode
multilanguage support
ultrasound area size
font size
B+M layout position, size
Image and video save / load formats:
AVI
JPG
BMP
PNG
TIF
XLSX
DCM (DICOM uncompressed)
DCM (DICOM-JPEG RGB/YBR)
DCM (DICOM-JPEG RGB/YBR Video)
TPD (Telemed Picture Data) – Raw Data
TVD (Telemed Video Data) – Raw Data
Raw Data formats TPD and TVD allow post-processing functions on saved images/video
(measurements, calculations, zoom, speckle reduction, gamma, palette, reporting etc.)
DICOM
Verification SCU
Modality Worklist (MWL) SCU
Modality Performed Procedure Step (MPPS) SCU
Store SCU (images, video)
Print SCU (grayscale, color)
Measurements and Calculations
Measurements and calculations: general, abdominal, obstetrics, gynecology, urology, vascular,
endocrinology, musculoskeletal, cardiology.
Doppler velocimetry calculations with manual and automatic PW trace line analysis
Power Supply
external power supply, 100~240V AC, 50~60 Hz
+12V, 2.5A input
Dimension, Weight
SmartUs EXT-1M
dimensions mm: 158 x 220 x 54
weight: Kg 1,4
SmartUs EXT-3M
dimensions mm: 155 x 212 x 80
weight: Kg 2,0
Ultrasound software
TELEMED Drivers Package (32/64‐bit Windows)
Echo Wave II software / Echo Wave II Touch (32/64‐bit Windows)
3DView plug-in (option)
PanoView plug-in (option)
SDK documentation / sample code (available by agreement)
Freeware software upgrades
Computer Requirements
Windows® based Notebook/Tablet PC/Desktop
Screen 1024×768 or more, IPS technology
CPU Intel i3/i5/i7 1.8 GHz or faster
2 Gb of RAM or more
USB 2.0 – USB 3.0 interface
Windows 7, Windows 8, Windows 10 (32/64-bit)
Customer Care and Technical Support
Real-time Customer support with remote control via Internet.
Freeware software upgrades.
SmartUs EXT-1M Kit includes:
Smart Us EXT-1M beamformer
USB cable
100~240 VAC, 50~60 Hz power supply (EN60601-1, UL2601-1 certified)
AC power cable
Software, assembly, set‐up manual, operation manual (USB pen drive)
- Latest development snapshot: This contains the latest features and fixes, but it is not tested as thoroughly as stable releases.
Editions
General Note:
- 32-bit applications are supported on both 32/64-bit versions of Windows.
- 64-bit applications are only supported on 64-bit versions of Windows.
- Plus applications running on different operating systems can exchange data between each other through OpenIGTLink.
Supported on Windows 10, Windows 8.1:
Telemed Driver Download For Windows 1000
- PlusApp-…-Win32: Generic 32-bit release. Executables are 32-bit applications.
- PlusApp-…-Win64: Generic 64-bit release. Executables are 64-bit applications. It can record more frames in memory and reconstruct larger volumes than the 32-bit release but less hardware devices are supported
- PlusApp-…-ThorLabs-Win32: Package to be used for connecting to ThorLabs spectrometers. Requires ThorLabs drivers installed (otherwise Plus applications will fail to start). Executables are 32-bit applications.
- PlusApp-…-Interson-MTC-3.7-Win32: Package to be used for connecting to Interson USB ultrasound probes. Requires Interson USB probe drivers installed (otherwise Plus applications will fail to start). With MicronTracker 3.7 SDK support. Executables are 32-bit applications.
- PlusApp-…-Telemed-Win32: Package to be used for connecting to Telemed Ultrasound systems. Executables are 32-bit applications.
- PlusApp-…-spryTrack-Telemed-Win32: Package to be used for connecting to Telemed Ultrasound systems and to spryTrack. Executables are 32-bit applications.
- PlusApp-…-fusionTrack-Win64: Package to be used for connecting to Atracsys fusionTrack. Executables are 64-bit applications.
Supported on Windows 10:
- PlusApp-…-Clarius-Win64: Package to be used for connecting to Clarius Ultrasound systems. Executables are 64-bit applications.
Supported on Windows 7 or Windows XP Embedded:
- PlusApp-…-Ultrasonix-5.7-Win32: Package to be used on Ultrasonix systems (running on Windows XP embedded or Windows 7 operating system); running Ultrasonix Exam software version between 5.7.0 and 6.0.2. MicronTracker and Microsoft Media Foundation imaging devices are not supported. Executables are 32-bit applications.
- PlusApp-…-Ultrasonix-6.1-Win32: Package to be used on Ultrasonix systems (running on Windows XP embedded or Windows 7 operating system); running Ultrasonix Exam software version 6.1.1 and later. MicronTracker and Microsoft Media Foundation imaging devices are not supported. Executables are 32-bit applications.
Other:
- PlusApp-…-StealthLink-Win32: Package to be used for connecting to Medtronic navigation systems through StealthLink interface on 32/64-bit, Windows 7 and Windows 8 systems. Requires StealthLink license. Package is available on request.
- PlusApp-…-BK-Win32: Package to be used for connecting to BK Ultrasound systems on 32/64-bit, Windows 7 and Windows 8 systems. Requires BK OEM interface license. Package is available on request.
- PlusApp-…-OptiTrack-Telemed-Win32: Package to be used for connecting to Telemed Ultrasound systems and to OptiTrack using Motive 2.0 on 32/64-bit, Windows 7 and Windows 8 systems. Executables are 32-bit applications. Package is available on request.
Mac OS X and Linux:
- Plus can be built and packaged for Linux and Mac OSX operating systems as described in the Developer's guide. If help is needed, submit an issue on the GitHub project page.
Supported devices in latest development snapshots
Win32 | Win64 | Telemed Win32 | Ultrasonix-5.7 Win32 | Ultrasonix-6.1 Win32 | MTC-3.7 Win32 | Interson-MTC-3.7 Win32 | ThorLabs Win32 | StealthLink | spryTrack-Telemed Win32 | fusionTrack Win64 | Clarius Win64 | |
NDI Polaris & Aurora | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
NDI Ascension | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | N |
NDI Certus | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | N |
MicronTracker (3.7) | Y | N | Y | N | N | Y | Y | N | Y | Y | N | N |
OpticalMarkerTracker | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
OpenCV Video | Y | Y | Y | N | N | N | Y | Y | N | Y | Y | Y |
Stealthlink | N | N | N | N | N | N | N | N | Y | N | N | N |
Ultrasonix (5.7) | N | N | N | Y | N | N | N | N | N | N | N | N |
Ultrasonix (6.1) | Y | N | N | N | Y | N | N | Y | Y | N | N | N |
Telemed | N | N | Y | N | N | N | N | N | Y | Y | N | N |
Interson | N | N | N | N | N | N | Y | N | N | N | N | N |
Microsoft Media foundation | Y | Y | Y | N | N | Y | Y | N | Y | Y | Y | Y |
Brachy steppers | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | N |
ThorLabs spectrometer | N | N | N | N | N | N | N | Y | N | N | N | N |
OptiTrack (Motive 1.10.3) | Y | N | Y | N | N | Y | Y | Y | N | Y | N | N |
OptiTrack (Motive 2.1.1) | N | Y | N | N | N | N | N | N | N | N | Y | Y |
Intel RealSense | Y | Y | Y | N | N | Y | Y | Y | N | Y | Y | Y |
spryTrack | N | N | N | N | N | N | N | N | N | Y | N | N |
fusionTrack | N | N | N | N | N | N | N | N | N | N | Y | N |
Clarius | N | N | N | N | N | N | N | N | N | N | N | Y |
Verification SCU
Modality Worklist (MWL) SCU
Modality Performed Procedure Step (MPPS) SCU
Store SCU (images, video)
Print SCU (grayscale, color)
Measurements and Calculations
Measurements and calculations: general, abdominal, obstetrics, gynecology, urology, vascular,
endocrinology, musculoskeletal, cardiology.
Doppler velocimetry calculations with manual and automatic PW trace line analysis
Power Supply
external power supply, 100~240V AC, 50~60 Hz
+12V, 2.5A input
Dimension, Weight
SmartUs EXT-1M
dimensions mm: 158 x 220 x 54
weight: Kg 1,4
SmartUs EXT-3M
dimensions mm: 155 x 212 x 80
weight: Kg 2,0
Ultrasound software
TELEMED Drivers Package (32/64‐bit Windows)
Echo Wave II software / Echo Wave II Touch (32/64‐bit Windows)
3DView plug-in (option)
PanoView plug-in (option)
SDK documentation / sample code (available by agreement)
Freeware software upgrades
Computer Requirements
Windows® based Notebook/Tablet PC/Desktop
Screen 1024×768 or more, IPS technology
CPU Intel i3/i5/i7 1.8 GHz or faster
2 Gb of RAM or more
USB 2.0 – USB 3.0 interface
Windows 7, Windows 8, Windows 10 (32/64-bit)
Customer Care and Technical Support
Real-time Customer support with remote control via Internet.
Freeware software upgrades.
SmartUs EXT-1M Kit includes:
Smart Us EXT-1M beamformer
USB cable
100~240 VAC, 50~60 Hz power supply (EN60601-1, UL2601-1 certified)
AC power cable
Software, assembly, set‐up manual, operation manual (USB pen drive)
- Latest development snapshot: This contains the latest features and fixes, but it is not tested as thoroughly as stable releases.
Editions
General Note:
- 32-bit applications are supported on both 32/64-bit versions of Windows.
- 64-bit applications are only supported on 64-bit versions of Windows.
- Plus applications running on different operating systems can exchange data between each other through OpenIGTLink.
Supported on Windows 10, Windows 8.1:
Telemed Driver Download For Windows 1000
- PlusApp-…-Win32: Generic 32-bit release. Executables are 32-bit applications.
- PlusApp-…-Win64: Generic 64-bit release. Executables are 64-bit applications. It can record more frames in memory and reconstruct larger volumes than the 32-bit release but less hardware devices are supported
- PlusApp-…-ThorLabs-Win32: Package to be used for connecting to ThorLabs spectrometers. Requires ThorLabs drivers installed (otherwise Plus applications will fail to start). Executables are 32-bit applications.
- PlusApp-…-Interson-MTC-3.7-Win32: Package to be used for connecting to Interson USB ultrasound probes. Requires Interson USB probe drivers installed (otherwise Plus applications will fail to start). With MicronTracker 3.7 SDK support. Executables are 32-bit applications.
- PlusApp-…-Telemed-Win32: Package to be used for connecting to Telemed Ultrasound systems. Executables are 32-bit applications.
- PlusApp-…-spryTrack-Telemed-Win32: Package to be used for connecting to Telemed Ultrasound systems and to spryTrack. Executables are 32-bit applications.
- PlusApp-…-fusionTrack-Win64: Package to be used for connecting to Atracsys fusionTrack. Executables are 64-bit applications.
Supported on Windows 10:
- PlusApp-…-Clarius-Win64: Package to be used for connecting to Clarius Ultrasound systems. Executables are 64-bit applications.
Supported on Windows 7 or Windows XP Embedded:
- PlusApp-…-Ultrasonix-5.7-Win32: Package to be used on Ultrasonix systems (running on Windows XP embedded or Windows 7 operating system); running Ultrasonix Exam software version between 5.7.0 and 6.0.2. MicronTracker and Microsoft Media Foundation imaging devices are not supported. Executables are 32-bit applications.
- PlusApp-…-Ultrasonix-6.1-Win32: Package to be used on Ultrasonix systems (running on Windows XP embedded or Windows 7 operating system); running Ultrasonix Exam software version 6.1.1 and later. MicronTracker and Microsoft Media Foundation imaging devices are not supported. Executables are 32-bit applications.
Other:
- PlusApp-…-StealthLink-Win32: Package to be used for connecting to Medtronic navigation systems through StealthLink interface on 32/64-bit, Windows 7 and Windows 8 systems. Requires StealthLink license. Package is available on request.
- PlusApp-…-BK-Win32: Package to be used for connecting to BK Ultrasound systems on 32/64-bit, Windows 7 and Windows 8 systems. Requires BK OEM interface license. Package is available on request.
- PlusApp-…-OptiTrack-Telemed-Win32: Package to be used for connecting to Telemed Ultrasound systems and to OptiTrack using Motive 2.0 on 32/64-bit, Windows 7 and Windows 8 systems. Executables are 32-bit applications. Package is available on request.
Mac OS X and Linux:
- Plus can be built and packaged for Linux and Mac OSX operating systems as described in the Developer's guide. If help is needed, submit an issue on the GitHub project page.
Supported devices in latest development snapshots
Win32 | Win64 | Telemed Win32 | Ultrasonix-5.7 Win32 | Ultrasonix-6.1 Win32 | MTC-3.7 Win32 | Interson-MTC-3.7 Win32 | ThorLabs Win32 | StealthLink | spryTrack-Telemed Win32 | fusionTrack Win64 | Clarius Win64 | |
NDI Polaris & Aurora | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
NDI Ascension | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | N |
NDI Certus | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | N |
MicronTracker (3.7) | Y | N | Y | N | N | Y | Y | N | Y | Y | N | N |
OpticalMarkerTracker | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
OpenCV Video | Y | Y | Y | N | N | N | Y | Y | N | Y | Y | Y |
Stealthlink | N | N | N | N | N | N | N | N | Y | N | N | N |
Ultrasonix (5.7) | N | N | N | Y | N | N | N | N | N | N | N | N |
Ultrasonix (6.1) | Y | N | N | N | Y | N | N | Y | Y | N | N | N |
Telemed | N | N | Y | N | N | N | N | N | Y | Y | N | N |
Interson | N | N | N | N | N | N | Y | N | N | N | N | N |
Microsoft Media foundation | Y | Y | Y | N | N | Y | Y | N | Y | Y | Y | Y |
Brachy steppers | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | N |
ThorLabs spectrometer | N | N | N | N | N | N | N | Y | N | N | N | N |
OptiTrack (Motive 1.10.3) | Y | N | Y | N | N | Y | Y | Y | N | Y | N | N |
OptiTrack (Motive 2.1.1) | N | Y | N | N | N | N | N | N | N | N | Y | Y |
Intel RealSense | Y | Y | Y | N | N | Y | Y | Y | N | Y | Y | Y |
spryTrack | N | N | N | N | N | N | N | N | N | Y | N | N |
fusionTrack | N | N | N | N | N | N | N | N | N | N | Y | N |
Clarius | N | N | N | N | N | N | N | N | N | N | N | Y |
Notes
Telemed Driver Download For Windows 10 Free
- Note: some browsers may indicate that the installers are malicious files. This is a common problem when offering download of executable files (for example see discussion here). If you doubt the safety of a package, download it and before you run it, submit to online malware scanners, such as https://www.metascan-online.com or https://www.virustotal.com/.
- If Plus applications fail to start, install Microsoft Visual Studio redistributable packages:
- MSVCP120.dll missing => install VS2013 redistributable and restart your computer
- MSVCP140.dll missing => install VS2015 redistributable and restart your computer
- Embedded XP requires XP SP3 and Visual Studio 2013 Redistributable x86 installed.
- VCRUNTIME140_1.dll missing => install VS2015-2019 redistributable